Multi Room Heat Pumps
Brand :AIM
Product origin :China
Delivery time :20days
Supply capacity :5000units/month
Unique Features:
Competive economical heating/cooling or hot water solutions;
Reliable and high efficient flexible Copeland scroll (EVI) compressor;
Cascade installation to provide large heating/cooling capacity for commercial projects;
Convenient installation with built-in hydraulic kit for 10kw, 14kw and 17kw domestic models;
Powerful heating/cooling effect with fast defrost;
Heat pump manager has been installed in domestic models;
Centralization of control by micro computer;
Wifi function for connecting with mobile phone if request.
Working Principle:
Compressor gets the low temperature and low pressure air refrigerant from evaporator,
then turn it into high temperature and high pressure air,
this air gets into the condenser to exchange the heat with water,
then the condensed air become low temperature fluid and release lots of heat energy.
Water gets this heat energy and become hotter and hotter.
This high pressure and low temperature fluid become low pressure by the primary flow meter device.
This low pressure and low temperature fluid, gets into the evaporator, Under the function of rotation fan, heat energy from air is absorbed by the fluid and becomes low pressure refrigerant,
then is absorbed by compressor, recycling to produce the hot water.
Air and water source heat pumps Main components and Effect:
1. Compressor: Famous Brand Panasonic, Sanyo, Mitsubishi,Toshiba Rotary Compressor or Sanyo, Copeland, DAIKIN Scroll Compressor with environmentally friendly Refrigerant gas R407C/R410A/R134a/R417A
Effect: Compress and transport cycle fluid from low temperature low pressure to high temperature high pressure, it’s the heart of heat pump system.
2. Evaporator or heat exchanger: Hydrophilic aluminum foil Finned tube Heat Exchanger.
Effect: It’s the cooling output facility. Evaporate the refrigerant liquid which flowing through the expansion valve to absorb the heat from the cooled object, so achieve the purpose of cooling.
3. Condenser: Coil type, plate type, casing type, High efficiency tube in shell heat ex-changer or Titanium heat ex-changer.
Effect: It’s the heating output facility. Heat absorbed from the evaporator with the converted heat by compressor power consumption is carried away by cooled medium in the condenser, to achieve the purpose of heating.
4. House casing: anti corrosion and rustproof Stainless steel or Spray coating metal plate for whole set of casing, Buttress and frame system, Electric Control Box etc.
5. Microprocessor automatic Controller sets: LCD touch screen Wifi Display, Neatly wiring PCB Board in individual controller box, Whole sets of temp sensors, Capacitors, Transformer.
6. Copper Pipes: throttling device, pipes connect all system, compressor, heat ex-changer, EEV and so on sub-assembly.
7. Thermostatic expansion valve or Japanese Sanhua Electronic Expansion valve and 4-Way Valve
EEV Effect: For circulating fluid Throttling depressurization and adjust the flow of cycle fluid into the evaporator.
Model | DKFXJT-3.0-11.2I/FR | LSQ-5HJ/FR | JT-20II/FR | JT-28II/FR | JT-45II/FR |
Horse power (HP) | 3 | 5 | 6 | 10 | 12 |
Heating capacity (kW) | 8 | 14.7 | 19.8 | 27.5 | 40 |
Cooling capacity (kW) | 7.5 | 12.5 | 18 | 25 | 37.8 |
Heating power input (kW) | 2.4 | 4.2 | 6.2 | 8.6 | 12.5 |
Cooling power input (kW) | 2.5 | 4.6 | 6.5 | 8.8 | 13.5 |
Heating COP | 3.33 | 3.50 | 3.19 | 3.20 | 3.20 |
Cooling EER | 3.00 | 2.72 | 2.77 | 2.84 | 2.80 |
Heating current input (A) | 15 | 8.6 | 11 | 17 | 22 |
Cooling current input | 16 | 9.2 | 12 | 18 | 24 |
Max current input | 18 | 10.32 | 13.2 | 20.4 | 26.4 |
Power supply (V/Ph/Hz) | 220/1/50 | 380/3/50 | 380/3/50 | 380/3/50 | 380/3/50 |
Refrigerant / Charge(kg) | R22 or R410A /2.2 | R22,R410A /4 | R22,R410A /4.5 | R22,R410A/4*2 | R410A / 4.5*2 |
Compressor No. (pcs) | 1 | 1 | 1 | 2 | 2 |
Compressor type | Scroll | Scroll | Scroll | Scroll | Scroll |
Heating water outlet temp range | 40/45℃ | 20 | 40/45℃ | 40/45℃ | 40/45℃ |
Cooling water outlet temp range | 7/12℃ | 7/12℃ | 7/12℃ | 7/12℃ | 7/12℃ |
Pipe diameter | 1" | 1.5" | 1.5‘’ | 1.5" | 1.5" |
Water flow (m³/h) | 3 | 5 | 6 | 10 | 15 |
Water side pressure loss | 35Kpa | 35Kpa | 35Kpa | 35Kpa | 35Kpa |
Water flow pressure drop | 0.01-0.02 Mpa | 0.01-0.02 Mpa | 0.01-0.02 Mpa | 0.01-0.02 Mpa | 0.01-0.02 Mpa |
Max pressure of suction / discharge | 0.8 / 2.8Mpa | 0.8 / 2.8Mpa | 0.8 / 2.8Mpa | 0.8 / 2.8Mpa | 0.8 / 2.8Mpa |
Running noise dB(A) | 66 | 68 | ≤68 | ≤68 | ≤68 |
Protection / Anti-electric shock rate | IPX4 / Class I | IPX4 / Class I | IPX4 / Class I | IPX4 / Class I | IPX4 / Class I |
Running ambient temp. | -10~+43℃ | -10~+43℃ | -10~+43℃ | -10~+43℃ | -10~+43℃ |
Net weight (kg) | 88 | 125 | 138 | 230 | 300 |
Top type dimension (LxWxH) | 717x717x860=0.44m³ | 717x717x960=0.49m³ | 805x805x960=0.62m³ | 1424x1424x960=1.95m³ | 1600x1600x960=2.46m³ |
Capacity and power input based on the GB/T18430.2-2008, GB/T21362-2008 conditions:
Heating mode: Water flow 0.172m³/(hkW), hot water outlet temp. 45℃, ambiemt temp. (DB/WB) 7/6℃
Cooling mode: Water flow 0.172m³/(hkW), cold water outlet temp. 7℃, ambiemt temp. 35℃
Production process of heat pump
1. Base plates go online
2. Install compressors, condensers and evaporators
3. Assemble and weld copper pipes
4. Recharged with Nitrogen
5. Water-inspection (Check if exist in air leakage)
6. Discharge Nitrogen
7. Vacuum air-removed
8. Add refrigerant
9. Halogen inspection
10. Fix fan component
11. Install electrical control
12. Security checks (Insulation, Ground connection, Dielectric Strength test, Leakage)
13. Run commodity inspection (The noise of components and parts, Function, Timing, shutdown, current, Difference in temperature)
14. Stick nameplate and connection diagram
15. Document attached (Product Manuals, instructions)
16. Final inspection (Appearance parts)
17. Packing
18. Tape-out
AIM has Professional Testing laboratory was built about $450,000, which have a whole set testing:
1) Standard heating, cooling
2) Simulate Low and High temp working condition, a variety of ambient temp, indoor temp and outdoor temp.
3) Power consumption
4) COP and SEER
5) Defrosting
6) Air conditioner, water source, air source and hot water heat pump performance and capacity reliability testing
7) Controller function testing
8) Test goods at all kinds of power supply
9) Setting Temp ranges -25~60℃, its accuracy is +-0.2℃; Humidity ranges 20%~99%, its accuracy is +-1%.
10) DC inverter water flow and air flow control (100m³/h ~ 3000 m³/h)
11) Temp, pressure, power collector