Trinity For Heating
Brand :AIM
Product origin :China
Delivery time :20days
Supply capacity :8000units/month
Features:
Energy saving more than 75%
Economic & durable
Famous brand compressor
Convenient for maintenance, operation, easy installation
Description:
Multifunctional heat pump provides room heating, cooling and free domestic hot water for resident and commercial application.
Using free renewable energy from the air, the units are highly efficient with low running costs, low carbon emission and are able to be integrated with energy systms such as solar heater, radiator, under floor pipes and boiler.
Multifunctional Heat Pump air to water trinity for heating, cooling and free hot water R410A, R134a Daikin
Model | JT-20II/MWFR | JT-28II/MWFR | JT-45II/MWFR | JT-60II/MWFR | JT-68II/MWFR | JT-80II/MWFR | JT-100II/MWFR | JT-130II/MWFR | |||||||||
Horse power | HP | 6 | 10 | 12 | 15 | 20 | 25 | 30 | 40 | ||||||||
Heating or cooling Capacity | Heating | Cooling | Heating | Cooling | Heating | Cooling | Heating | Cooling | Heating | Cooling | Heating | Cooling | Heating | Cooling | Heating | Cooling | |
Capacity | kW | 19.8 | 18 | 27.5 | 25 | 40 | 37.8 | 56 | 50 | 64 | 59.6 | 76 | 70 | 112 | 98.5 | 145 | 132 |
Power Input | kW | 6.2 | 6.5 | 8.6 | 8.8 | 12.5 | 13.5 | 16.6 | 17.6 | 20 | 21.3 | 24 | 25 | 34 | 35.2 | 43 | 46 |
Current Input | A | 11.00 | 12.00 | 17.00 | 18.00 | 22 | 24 | 30 | 32 | 38 | 40 | 44 | 48 | 60 | 64 | 78 | 80 |
Heating COP or Cooling EER | 3.19 | 2.77 | 3.20 | 2.84 | 3.20 | 2.80 | 3.37 | 2.84 | 3.20 | 2.80 | 3.17 | 2.80 | 3.29 | 2.80 | 3.37 | 2.87 | |
Rated Voltage / frequency | V/Hz | 380-415V/50Hz/3Ph | 380-415V/50Hz/3Ph | ||||||||||||||
Max Power Input | kW | 7.44 | 7.8 | 10.32 | 10.56 | 15 | 16.2 | 19.92 | 21.12 | 24 | 25.56 | 28.8 | 30 | 40.8 | 42.24 | 51.6 | 55.2 |
Max Current | A | 13.2 | 14.4 | 20.4 | 21.6 | 26.4 | 28.8 | 36 | 38.4 | 45.6 | 48 | 52.8 | 57.6 | 72 | 76.8 | 93.6 | 96 |
Rated hot water output | L/H | 560 | 800 | 1200 | 1600 | 2000 | 2400 | 3200 | 4000 | ||||||||
COP in Heating 40℃/45℃ at 7℃/6℃ ambient temp. | 3.40 | - | 3.25 | - | 3.51 | - | 3.54 | - | 3.62 | - | 3.58 | - | 3.56 | - | 3.12 | - | |
COP in Cooling 12℃/7℃ at 35℃/24℃ ambient temp. | - | 2.81 | - | 2.85 | - | 2.79 | - | 2.85 | - | 2.83 | - | 2.78 | - | 2.82 | - | 2.81 | |
Refrigerant type / Charge | … / kg | R22 or R410A / 4.5 | R22 or R410A / 4*2 | R22 or R410A /4.5*2 | R22 or R410A /7.5*2 | R22 or R410A /9*2 | R22 or R410A /11*2 | R22 or R410A /7.5*4 | R22 or R410A /9.6*4 | ||||||||
Water connections | inch | 1.5" | 1.5" | 1.5" | 1.5" | 2" | 2" | 2.5" | 4" | ||||||||
Heating / Cooling Water pipe connection diameter | inch | 19 | 19 | 19 | 22 | 28 | 28 | 28 | 28 | ||||||||
Supplementary heater vessel (not bulit-in) | L | 10 | 10 | 20 | 20 | 20 | 20 | 20 | 20 | ||||||||
Hot water circulation flow | m³/h | 6 | 10 | 15 | 20 | 25 | 35 | 40 | 50 | ||||||||
Water side pressure loss | kPa | 35 | 35 | 35 | 35 | 35 | 35 | 35 | 35 | ||||||||
Water flow pressure drop | Mpa | 0.01-0.02 | 0.01-0.02 | 0.01-0.02 | 0.01-0.02 | 0.01-0.02 | 0.01-0.02 | 0.01-0.02 | 0.01-0.02 | ||||||||
Suction/discharge max pressure | Mpa | 0.8 / 2.8 | 0.8 / 2.8 | 0.8 / 2.8 | 0.8 / 2.8 | 0.8 / 2.8 | 0.8 / 2.8 | 0.8 / 2.8 | 0.8 / 2.8 | ||||||||
Unit protection class | IP | IPX4 | IPX4 | IPX4 | IPX4 | IPX4 | IPX4 | IPX4 | IPX4 | ||||||||
Anti-electric shock class | Class 1 | Class 1 | Class 1 | Class 1 | Class 1 | Class 1 | Class 1 | Class 1 | |||||||||
Operating in Ambient temp. | ℃ | (-15℃~45℃) | (-15℃~45℃) | (-15℃~45℃) | (-15℃~45℃) | (-15℃~45℃) | (-15℃~45℃) | (-15℃~45℃) | (-15℃~45℃) | ||||||||
Hot water outlet temp | ℃ | 55~60 | 55~60 | 55~60 | 55~60 | ||||||||||||
Cool water outlet temp | 7/12℃ | 7/12℃ | 7/12℃ | 7/12℃ | |||||||||||||
Sound pressure level (1m) | dB (A) | 65 | 68 | 68 | 72 | 72 | 72 | 74 | 74 | ||||||||
PLC Controller | Yes Digital LCD Controller | Yes Digital LCD Controller | Yes Digital LCD Controller | Yes Digital LCD Controller | Yes Digital LCD Controller | ||||||||||||
Net weight(Top/side type) | kg | 138 | 230 | 300 | 500 | 680 | 800 | 1200 | 1350 | ||||||||
Net dimension(Top type) | mm | 805x805x960=0.62m³ | 1424x1424x960=1.95m³ | 1600x1600x960=2.46m³ | 2000x1100x1980=3.96m³ | 2000x1100x1980=3.96m³ | 2000x1680x1980=6.65m³ | 2000x1800x1980=7.13m³ | 2000x1800x1980=7.13m³ | ||||||||
Net dimension(Side type) | mm | - | - | - | - | - | - | - | - |
Capacity and power input based on the GB/T18430.2-2008、GB/T21362-2008 conditions:
Heating mode: Water flow 0.172m³/(hkW), hot water outlet temp. 45℃, ambiemt temp. (DB/WB) 7/6℃
Cooling mode: Water flow 0.172m³/(hkW), cold water outlet temp. 7℃, ambiemt temp. 35℃
Hot water mode: Water flow 0.172m³/(hkW), hot water inlet/outlet temp. 15/55℃, ambiemt temp. (DB/WB) 20/15℃
AIM is a high-tech new energy and high efficient factory built in 2011 year occupied more than 22,000m² area, concentrates on researching and developing stainless steel air source, water and ground source, central air-conditioner, water tank etc, is one of the top companies which has a complete product chain.
As a Drafting Committee of Multifunctional air source heat pump, AIM has dozens of core intellectual property rights of the patented technology, has been rated as the national high-tech new energy enterprise, industry outstanding and top besting-selling famous brand, successfully listed in Equity Exchange Co., Ltd in 2016 (Stock Code: 220079)
AIM has a strict standard of inspecting for product quality, a completely production management control system. Gained the certificates of ISO9001, ISO14001, CCC, CE, TUV, Industrial production license and so on.
Ideal life, made life comfortable, starting from AIM.
AIM’s main heat pump series:
1. Split domestic hot water heat pump,
2. All in one hot water heat pump,
3. Swimming pool heat pump,
4. Commercial hot water heat pump,
5. EVI air source heat pump,
6. Instant hot water heat pump,
7. High temp heat pump,
8. Dryer air to water heat pump,
9. Chiller heating and cooling air conditioner;
10. DC inverter air to water heat pump,
11. Multifunctional air source heat pump,
12. Water to water heat pump,
13. Water tank
Unique features of AIM Heat Pumps:
1. It can display top and bottom temp of the water tank, check the temp of coil, ambient, exhaust temp, etc;
2. It recalls all kinds of parameters when outages and it will resume operations after have electricity automatically.
3. Clock keeps running after outages so it needn’t to re-adjust it usually.
4. Off-peak power use function, start up and shutdown by itself at cycle time in 24 hours.
5. Set and revise parameters freely.
6. E-heater function.
7. Automatic and forcible defrost.
8. Waterproof bottoms, Liquid Crystal Display Screen Display including backlights.
9. Have Perfect control and protection functions: 1) temperature sensor breakdown: top and bottom of water tank, Coil, Return air, Exhaust air, Outside ambient temp; 2) high and low pressure protection, Exhaust air temp protection.
10. Check the Trouble codes display, it can refer why compressor doesn’t start up or stop, and has Key-Lock Function.
11. It can display water temp when startup and shutdown heat pump.
12. Electronic expansion valve control automatically.
13. Temp set ranges from 10℃ to 90℃.
14. Working ambient temp -25℃ to 43℃.
Sales Manager: Ms. Jenny
Guangdong AIM Energy Saving Technology Co., Ltd.
Add: Longchuan Dengyun Zhen Shenzhen Nanshan(Longchuan) industrial transfer park,Heyuan,Guangdong
Cell & WhatsApp & Wechat: +86 15919073687
Jenny Zeng. Skype: jenny02025
E-mail: jennyzeng5@foxmail.com
1:“Quality is our culture” 90% of AIM heat pump production equipment is imported from USA, Japan and Germany.
2:“With us your money in safe” full refund in case of bad quality or delay delivery time we also accept payment by Paypal.
3:“Time is gold” for you and for us, we have professional team work whom can making nice quality in short time.
4:“Quality is the soul of an enterprise” we had the honor to serve big customers (We gained the outstanding best selling).
AIM has Professional Testing laboratory was built about $450,000, which have a whole set testing:
1) Standard heating, cooling
2) Simulate Low and High temp working condition, a variety of ambient temp, indoor temp and outdoor temp.
3) Power consumption
4) COP and SEER
5) Defrosting
6) Air conditioner, water source, air source and hot water heat pump performance and capacity reliability testing
7) Controller function testing
8) Test goods at all kinds of power supply
9) Setting Temp ranges -25~60℃, its accuracy is +-0.2℃; Humidity ranges 20%~99%, its accuracy is +-1%.
10) DC inverter water flow and air flow control (100m³/h ~ 3000 m³/h)
11) Temp, pressure, power collector
Working principle:
Compressor absorbs low temperature and low pressure refrigerant gas from the evaporator, then refrigerant compressed to high temperature and high pressure gas. The high temperature and high pressure gas goes into the condenser through fan to exchange heat with the air, and condensed into cryogenic liquid in the condenser and give off a lot of heat.
The air absorbs the heat and the temperature increasing. High pressure and low temperature liquid is throttled and depressurized through the expansion valve, absorbs heat from the surrounding air and volatilize into low pressure gas by fan in the evaporator, being compressed in the compressor, this repeated cycle, so as to continuously rise the water temperature.